Afx ALF16226QMVSNLA Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Éclairage Afx ALF16226QMVSNLA. AFX ALF16226QMVSNLA User Manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Algiers Flushmount Fluorescent Fixtures
Models: ALF218MV, ALF226MV
Page 1 of 1 8060686 R1
Limited Factory Warranty
AFX Lighting, Inc. warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions
for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit
.
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that all wiring be performed by a qualified
electrician. This fixture must be wired in accordance with all national
and local electrical codes.
Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.
Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing). Model numbers ending in
MV are designed for use in a 120-277VAC, 60Hz fused circuit (Do
not use on a dimming circuit).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry
or damp locations only.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or servicing any part of this fixture.
B. Remove fixture from carton; remove ceiling pan and diffuser assembly.
C. Thread two (3) screws (provided) into the cross gem bar (2). Leave about ½” screws length exposed.
D. Install gem bar (2) (provided)) on the junction box (not provided) by securing it with two (1) screws (provided).
2. Wiring
All wiring must take place inside junction box. Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for
at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified
electrician before installing.
A. This unit will not operate properly unless connected to a
“grounded” electrical circuit. Electrical shock, over heating, low
or no light output, and shortened lamp life can result if proper
grounding is not done. Securely attach green (or green and
yellow) wire to ground supply wire.
B. For wiring ballast power leads and power supply wires use
Ballast disconnect Instructions (provided).
C. Tuck all connections neatly into junction box.
3. Mounting
A. Align the backpan (4) keyslots with screws (3). Insert two
screws (3) through the keyslot openings. Twist backpan and
secure it by tightening screws (3).
4. Lamps
A. Install compact fluorescent lamps (5) (not provided) into the
sockets (7).
5. Diffuser mounting
A. Align diffuser (9) mounting holes with the two backpan
threaded bushing (6).
B. Install diffuser assembly (9) by securing it with two
thumbscrews (8) screws (provided).
6. Power to the fixture can now be restored.
Vue de la page 0
1

Résumé du contenu

Page 1 - Safety Precautions

Algiers Flushmount Fluorescent Fixtures Models: ALF218MV, ALF226MV Page 1 of 1 80606

Modèles reliés ALF16218QMVKBLA

Commentaires sur ces manuels

Pas de commentaire